SITE VISIT REPORT
Ahmed Al Mansoori
Apartment 1204 · Marina Gate 1
Dubai Marina, Dubai
M Visited by Michael — arrived 11:30

1 · Water source for installation

Under-sink cold feed is a 1/2" braided flex from the isolation valve behind the left cabinet. There is enough space for the RIO unit next to the disposer. Feed runs 60 cm along the back wall. Recommend replacing the flex hose — the current one is 6+ years old and starting to bulge near the valve.

2 · Water pressure

Kitchen faucet 3.2 bar Master washroom 2.8 bar Shower 2.6 bar

Kitchen and washroom are comfortable. Shower reading dropped noticeably when the washing machine ran — building supply may be marginal at peak times. RIO is fine at these numbers; PRO would want a boost pump.

3 · Water flow rate

Kitchen tap 9 L/min

Timed a 1-litre jug in 6.6 seconds → ~9 L/min at the kitchen cold tap. Enough headroom for any of our drinking-water systems.

4 · Water quality

Slight chlorine smell Clear — no colour

Customer says the water tastes "like a swimming pool" in the morning after the tank has stood overnight — improves by the afternoon. No yellow water, no visible rust. She stopped drinking from the tap two years ago. Wants a filter mainly for taste, then peace of mind.

5 · Pipe size and type

Inlet 1/2" Existing pipe: PEX / braided flex

Feed to the tap is braided PEX. No visible rust or corrosion, but two of the compression joints under the sink are hand-tight only — I've re-torqued them. Recommend the customer keeps an eye on the seal for a couple of weeks.

6 · Drainage

Not applicable — the recommended system doesn't backwash.

7 · Installation space & access

Under-sink cabinet has 45cm of horizontal space next to the disposer — enough for the RIO. Faucet hole on the granite worktop is a standard 32mm — the WaterClub tap fits without drilling. Enough headroom to swap the sediment filter without pulling the whole unit.

8 · Electrical supply

Socket within 1.5m Switched & safe No extension needed

Existing 13A socket at the back of the cabinet is on the kitchen ring, tested with a plug-in tester — earth, live, neutral all correct. Fine for the RIO pump.

9 · Condition of the main source

Isolation valve turns Minor leak — flex hose Pressure good

The isolation valve is stiff but turns. The braided flex from valve to tap is bulging near the collar — see photos on section 1 — we'll replace it as part of the install and it's included in the quote. Otherwise everything reads healthy.

10 · Other observations

Aged fittings

Building maintenance requires 24-hour notice before any work is done — you'll schedule this yourself. Also discussed a chiller for the shower (Dubai warm-water) — we've left the maintenance page open on your phone for reference.